HP
3325B
Remote
Operation
Command
Set
Command
Syntax
The
following
conventions
apply
to
the
HP
3325B
HP-IB
commands:
The
HP
3325B
accepts
data
in
7-bit
ASCII
code
and
ignores
the
8th
(parity)
bit.
All
spaces
and
lower
case
alphabetic
characters
are
ignored
by
the
HP
3325B;
they
may
be
used
to
improve
program
readability.
Under
HP-IB
control,
two
data
transfer
modes
are
available.
Refer
to
the
MD
command
for
more
detail.
An
asterisk
or
line
feed
is
required
to
terminate
a
command
string
in
data
transfer
mode
2.
A
semicolon
can
be
used
to
separate
commands
(recommended
but
not
required).
Range
values
may
be
in
integer,
real,
or
exponential
form.
For
positive
values,
only
the
first
eleven
digits
of
the
mantissa
are
used.
For
negative
values,
only
the
first
ten
digits
of
the
mantissa
are
used.
Leading
zeros
before
the
decimal
point
are
ignored.
2-17

Table of Contents

Other manuals for HP 3325B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3325B and is the answer not in the manual?

HP 3325B Specifications

General IconGeneral
BrandHP
Model3325B
CategoryPortable Generator
LanguageEnglish

Related product manuals