EasyManuals Logo

HP 5528A User Manual

HP 5528A
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #284 background imageLoading...
Page #284 background image
Mode
l 5528A
Errors and E
rr
or Messages
SECTION 17
ERRORS
AND ERROR
MESSAGES
Table
1
7-1
provides a listing of the
la
se
r
Mea
s
urement
Syste
m
's
error
me
ss
ag
es,
their
meaning
s,
and action you
ca
n take to try to eliminate the error.
If performing the indicated
"Act
ion" does not eliminate the error, refer
to
the
la
se
r
Me
as
ur
eme
nt
Sys
tem
's
Se
rvi
ce
Manual.
Table
17-1
.
La
ser
Measuremenr
Sy
srem
Erro
r Messages
M
essage
Meaning
Action
A Error
Err
or
in
"ave
ra
ge"
value
of
MATl
This m
ea
ns that you are tryi
ng
to vi
ew
the
TEMP
ave
ra
ge rnaterial
tempe
rature,
but
one
or
m
ore
material
temperature
sensors a
rc
indi
-
cating
an
erro
r.
Cycle t
hr
ough the MATERI
AL
TEMP
ERATURE
key to
det
er
mine
which sen-
50
r(s)
is
bad.
This error sh
ould
be cleared,
without
l
oss
of
meas
urement
inf
orm
ation,
by
removing
the
bad
se
n
so
r.
Unplu
g the bad sensor(s) and
have
it
repaired.
If the error condition per
sis
t
s,
th
e M eas
ure-
ment Displ
ay
may need
se
rvice.
AE
E
rror
Err
or
in
"tem
peratur
e"
va
l
ue
fr
om
This
erro
r should be clea red,
without
l
oss
of
Air
Sen
so
r (
see
V.O.
L.
i
nformation
) meas
ur
ement
inf
onna
tion, by
remo
ving the
bad sen
so
r.
AH Error
Error in
" humidit
y"
va
l
ue
from Air
Se
n
so
r (
see
V.O.l.
information
)
Unplug
the Air
Se
n
so
r and have it repaired.
AP
Error
Error in
" pre
ss
ure" value
fro
m
Aif
If the pr
oblem
persist
s,
the
Mea
s
urement
Se
n
so
r (
see
V.O.l.
inform
at
ion)
Di
spl
ay
ma
y need
se
rvice.
C E
rror
Co
mp
en
sa
tion
er
ror
(
due
to
a
se
n- This means that you are trying
to
view
the
so
r
ef
ror) (
see
V.O.
L.
inf
o
rmation
)
Ve
l
ocity-of-l
ight C
ompen
sa
tion value, but an
Air
Se
ns
or
error
(i.e. air
temperature
, pres-
sure, or
hum
idity) prevents the M
eas
ur
ement
Di
spl
ay
from
calcu lating
th
at
va
lue. Cycle
th r
oug
h the
V.O.l.
key to
determine
which
part
(s
}
of
the
Air
Se
nsor
is
bad.
This e
rror
s
hou
ld be
dea
r
ed,
without
lo
ss of
measurernent
inf
o
rmation
, by rerno
vi
ng the
bild
se
n
so
r. U
nplug
the
Air
Se
n
so
r and have
it repaired.
If the e
rr
or
co
nditi
on
per
sist
s,
the M
eas
ur
e-
ment Displ
ay
rnay need
se
rvice.
11

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 5528A and is the answer not in the manual?

HP 5528A Specifications

General IconGeneral
BrandHP
Model5528A
CategoryMeasuring Instruments
LanguageEnglish