Index
processors
power supply 2-21
removing 2-35
processor 2-37
replacing 2-37
processor fan module 2-9
socket locations 2-34
processor power module 2-39
SCSI backplane board 2-30
server into the rack 2-7
R
system board 2-44
rated input
requirements, input 6-1
current 6-1
ROM-Based Setup Utility (RBSU) 4-3
frequency 6-1
ROMPaq utility 4-4
power 6-1
voltage 6-1
S
rear panel, LEDs 5-3
SCSI backplane board rear unit identification LED switch 2-6
removing 2-30 Remote ROM Flash, Smart Components 4-4
replacing 2-30 removing
serial number, re-entering 2-44 access panel 2-8
server battery 2-42
dimensions 6-1 battery-backed write cache enabler 2-40
drive locations 2-10 DIMMs 2-32
maximum peak power 6-1 diskette drive 2-18
maximum wet-bulb temperature 6-2 expansion board in a PCI riser board
assembly 2-22 operating temperature range 6-2
power supply output power 6-1 fan assembly 2-24
powering down 2-5 hard drive 2-12
rated input current 6-1 hard drive blank 2-11
rated input frequency 6-1 heatsink 2-35
rated input power 6-1 memory 2-32
rated input voltage 6-1 optical device 2-14
rated steady state power 6-1 optical device/diskette drive interface
board 2-28 relative humidity, nonoperating 6-2
relative humidity, operating 6-2 PCI riser board assembly 2-22
removing from the rack 2-6 power converter module 2-25
replacing into the rack 2-7 power supply 2-19
shipping temperature range 6-2 processor 2-35
size 6-1 processor fan module 2-8
temperature range 6-2 processor power module 2-38
weight 6-1 SCSI backplane board 2-30
Smart Components for Remote ROM Flash 4-4 server from the rack 2-6
SmartStart Autorun Menu 4-5 system board 2-43
SmartStart Scripting Toolkit 4-5 replacing
SmartStart software 4-4 battery 2-43
socket locations battery-backed write cache enabler 2-41
processor 2-34 DIMMs 2-33
processor power module 2-34 diskette drive 2-19
socket locking lever 2-36 expansion board in a PCI riser board
assembly 2-23 specifications 6-1, 6-2
status LEDs See LEDs fan assembly 2-25
switches hard drive 2-13
debug LED (SW3) 5-7 hard drive blank 2-11
Power On/Standby 2-5 heatsink 2-37
redundant power supply/PCI (SW1) 5-6 memory 2-33
system maintenance (SW2) 5-6 optical device 2-15
symbols on equipment 2-2 optical device/diskette drive interface
board 2-29
PCI riser board assembly 2-22
HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide Index-3

Table of Contents

Other manuals for HP DL360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP DL360 and is the answer not in the manual?

HP DL360 Specifications

General IconGeneral
Processor Sockets2
CPUIntel Xeon Scalable
MemoryUp to 3TB DDR4
Form Factor1U Rack
Power SupplyRedundant Power Supplies, various wattage options
Network ControllerEmbedded 1Gb or 10Gb Ethernet
RAID SupportSmart Array RAID
Operating System SupportWindows Server, Linux, VMware
StorageUp to 10 SFF SAS/SATA/NVMe drives or 4 LFF SAS/SATA drives