Procedure
1. Power down the server.
2. Disconnect the power cord from the AC source, and then from the server.
3. Disconnect all peripheral cables from the server.
4.
Remove the front bezel.
5. Install the SFF drive.
6. Install the front bezel.
7. Connect all peripheral cables to the server.
8. Connect the power cord to the server power jack, and then to the AC source.
9.
Power up the server.
10. Determine the status of the server drives from the drive LED definitions.
11. To configure drive arrays, do one of the following:
If the drives are connected to the onboard LFF/SFF drive SATA port, use the Marvell Storage Utility or the
Marvell BIOS Utility.
If the drives are connected to a Smart Array storage controller board, use the
HPE Smart Storage
Administrator.
Install the SFF drive
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
T-15 Torx screwdriver
SFF drive converter option kit. This kit includes:
Drive converter tray
T-10 screws (4)
SFF drive option
Procedure
1. Install the SFF drive in the drive converter tray.