# Assign VFC 1 to VSAN 1.
[SwitchB-Vfc1] port trunk vsan 1
[SwitchB-Vfc1] quit
# Configure Ten-GigabitEthernet 1/0/1 as a trunk port, and assign the port to VLAN 10.
[SwitchB] interface ten-gigabitethernet 1/0/1
[SwitchB-Ten-GigabitEthernet1/0/1] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/0/1] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/0/1] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchB] vlan 10
[SwitchB-vlan10] fcoe enable vsan 1
[SwitchB-vlan10] quit
# Configure a static route in VSAN 1.
[SwitchB] vsan 1
[SwitchB-vsan1] fc route-static 010000 8 vfc 1
[SwitchB-vsan1] quit
Verifying the configuration
# FCping a switch from another switch, for example, FCping Switch B from Switch A.
[SwitchA] fcping fcid fffc02 vsan 1
FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break.
Reply from 0xfffc02: bytes = 128 time = 23 ms
Reply from 0xfffc02: bytes = 128 time = 9 ms
Reply from 0xfffc02: bytes = 128 time = 19 ms
Reply from 0xfffc02: bytes = 128 time = 14 ms
Reply from 0xfffc02: bytes = 128 time = 25 ms
--- 0xfffc02 fcping statistics ---
5 packet(s) transmitted
5 packet(s) received
0.00% packet loss