39
Setting fabric timers
The fabric operation involves the following timers:
Distributed service timeout period.
Error detection timeout period.
Resource allocation timeout period.
For more information about these timers, see FC-related protocols and standards.
You can set fabric timers in one of the following views:
System view—The setting takes effect on all VSANs.
VSAN view—The setting takes effect only on the VSAN.
If you set a fabric timer in both system view and VSAN view, the setting in VSAN view applies to the
VSAN.
Setting fabric timers in system view
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Set the global distributed
service timeout period.
fc timer distributed-services value
The default setting is 5000
milliseconds.
3. Set the global error
detection timeout period.
fc timer error-detect value
The default setting is 2000
milliseconds.
4. Set the global resource
allocation timeout period.
fc timer resource-allocation value
The default setting is 10000
milliseconds.
Setting fabric timers in VSAN view
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter VSAN view.
vsan vsan-id N/A
3. Set the distributed service
timeout period for the
VSAN.
timer distributed-services value
The default setting is 5000
milliseconds.
4. Set the error detection
timeout period for the
VSAN.
timer error-detect value
The default setting is 2000
milliseconds.
5. Set the resource allocation
timeout period for the
VSAN.
timer resource-allocation value
The default setting is 10000
milliseconds.

Table of Contents

Other manuals for HP FlexFabric 5700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexFabric 5700 series and is the answer not in the manual?

HP FlexFabric 5700 series Specifications

General IconGeneral
Layer SupportL2/L3
Routing ProtocolOSPF, BGP, RIP, IS-IS, Static Routing
Remote Management ProtocolSNMP, CLI, Web
FeaturesVXLAN
Compliant StandardsIEEE 802.1D, 802.1Q, 802.1w, 802.1s, 802.3ad
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (non-condensing)
VLANs4K