EasyManuals Logo

HP FlexFabric 5700 series Configuration Guide

HP FlexFabric 5700 series
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
58
Ste
p
Command
Remarks
2. Enter VSAN view.
vsan vsan-id N/A
3. Set the minimum LSR
refresh interval.
fspf min-ls-interval value The default setting is 5 seconds.
Setting the FSPF cost for an interface
Each link has a cost. The route selection algorithm uses this value to determine the best route. The smaller
the interface FSPF cost, the smaller the link cost.
To set the FSPF cost for an interface:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter VFC interface view.
interface vfc
interface-number
N/A
3. Set the FSPF cost for the
interface in a VSAN.
fspf cost value vsan vsan-id
The default setting for VFC interfaces are
100.
Setting the hello interval for an interface
The hello interval specifies the time between the hello packets sent periodically by the switch to discover
and maintain neighbor relationships.
NOTE:
The configured hello interval must be smaller than the dead interval and must be the same at the two ends
of the link.
To set the hello interval for an interface:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter VFC interface view.
interface vfc interface-number
N/A
3. Set the hello interval for the
interface in a VSAN.
fspf hello-interval value vsan
vsan-id
The default setting is 20 seconds.
Setting the dead interval for an interface
After two switches establish a neighbor relationship, they send hello packets at the hello interval to each
other to maintain the neighbor relationship. The dead interval specifies the interval during which at least
one hello packet must be received from a neighbor before the neighbor is considered nonexistent and
removed.

Table of Contents

Other manuals for HP FlexFabric 5700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexFabric 5700 series and is the answer not in the manual?

HP FlexFabric 5700 series Specifications

General IconGeneral
Layer SupportL2/L3
Routing ProtocolOSPF, BGP, RIP, IS-IS, Static Routing
Remote Management ProtocolSNMP, CLI, Web
FeaturesVXLAN
Compliant StandardsIEEE 802.1D, 802.1Q, 802.1w, 802.1s, 802.3ad
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (non-condensing)
VLANs4K