# Configure the switch to operate in FCF mode.
<SwitchC> system-view
[SwitchC] fcoe-mode fcf
# Enable the fabric configuration feature in VSAN 1.
[SwitchC] vsan 1
[SwitchC-vsan1] domain configure enable
# Set the domain ID to 3 in VSAN 1.
[SwitchC-vsan1] domain-id 3 static
# Disable FSPF in VSAN 1.
[SwitchC-vsan1] undo fspf enable
[SwitchC-vsan1] quit
# Create interface VFC 2.
[SwitchC] interface vfc 2
# Configure the mode of VFC 2 as E.
[SwitchC-Vfc2] fc mode e
# Bind VFC 2 to interface Ten-GigabitEthernet 1/0/2.
[SwitchC-Vfc2] bind interface ten-gigabitethernet 1/0/2
# Assign VFC 2 to VSAN 1 as a trunk port.
[SwitchC-Vfc2] port trunk vsan 1
[SwitchC-Vfc2] quit
# Configure Ten-GigabitEthernet 1/0/2 as a trunk port, and assign the port to VLAN 10.
[SwitchC] interface ten-gigabitethernet 1/0/2
[SwitchC-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchC-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10
[SwitchC-Ten-GigabitEthernet1/0/2] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchC] vlan 10
[SwitchC-vlan10] fcoe enable vsan 1
[SwitchC-vlan10] quit
4. FCping Switch C from Switch A.
[SwitchA] fcping fcid fffc03 vsan 1
FCPING fcid 0xfffc03: 128 data bytes, press CTRL_C to break.
Request time out
Request time out
Request time out
Request time out
Request time out
--- 0xfffc03 fcping statistics ---
5 packet(s) transmitted
0 packet(s) received
100.00% packet loss
The output shows that Switch A cannot reach Switch C.
5. Use the fctracert command to identify the faulty node.
[SwitchA] fctracert fcid fffc03 vsan 1

Table of Contents

Other manuals for HP FlexFabric 5700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexFabric 5700 series and is the answer not in the manual?

HP FlexFabric 5700 series Specifications

General IconGeneral
Layer SupportL2/L3
Routing ProtocolOSPF, BGP, RIP, IS-IS, Static Routing
Remote Management ProtocolSNMP, CLI, Web
FeaturesVXLAN
Compliant StandardsIEEE 802.1D, 802.1Q, 802.1w, 802.1s, 802.3ad
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (non-condensing)
VLANs4K

Related product manuals