{ Assign 50% of the interface bandwidth to Ethernet data traffic (traffic assigned to queue 0).
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af1 group 1 byte-count 1
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr be group 1 byte-count 1
# Assign the other queues to the SP group on interface Ten-GigabitEthernet 1/0/1.
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af2 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af3 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af4 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr ef group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr cs6 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr cs7 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] quit
6. Configure FCoE:
# Configure the switch to operate in FCF mode.
[SwitchA] fcoe-mode fcf
# Enable the fabric configuration feature in VSAN 100. By default, the fabric configuration feature
is enabled.
[SwitchA] vsan 100
[SwitchA-vsan100] domain configure enable
# Set the domain ID to 2.
[SwitchA-vsan100] domain-id 2 preferred
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF in VSAN 100.
[SwitchA-vsan100] fspf enable
[SwitchA-vsan100] quit
# Create interface VFC 1.
[SwitchA] interface vfc 1
# Configure the mode of VFC 1 as F.
[SwitchA-Vfc1] fc mode f
# Bind VFC 1 to interface Ten-GigabitEthernet 1/0/1.
[SwitchA-Vfc1] bind interface ten-gigabitethernet 1/0/1
# Assign VFC 1 to VSAN 100 as a trunk port.
[SwitchA-Vfc1] port trunk vsan 100
[SwitchA-Vfc1] quit
# Create interface VFC 10.
[SwitchA] interface vfc 10
# Configure the mode of VFC 10 as E.
[SwitchA-Vfc10] fc mode e
# Bind VFC 10 to Layer 2 aggregate interface 1.
[SwitchA-Vfc10] bind interface bridge-aggregation 1
# Assign VFC 10 to VSAN 100 as a trunk port.
[SwitchA-Vfc10] port trunk vsan 100
# Enable FSPF for VFC 10.
[SwitchA-Vfc10] undo fspf silent vsan 100
[SwitchA-Vfc10] quit

Table of Contents

Other manuals for HP FlexFabric 5700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexFabric 5700 series and is the answer not in the manual?

HP FlexFabric 5700 series Specifications

General IconGeneral
Layer SupportL2/L3
Routing ProtocolOSPF, BGP, RIP, IS-IS, Static Routing
Remote Management ProtocolSNMP, CLI, Web
FeaturesVXLAN
Compliant StandardsIEEE 802.1D, 802.1Q, 802.1w, 802.1s, 802.3ad
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (non-condensing)
VLANs4K