157
0x01(1) 48:33:43:2d:46:43:1C:1C [Principal]
0x02(2) 48:33:43:2d:46:43:1A:1A [Local]
The output shows that Switch C is selected as the principal switch, and the principal switch assigns
domain ID 1 to itself.
# Display the routing table information for VSAN 100.
[SwitchA] display fc routing-table vsan 100
Routing Table: VSAN 100
Destinations : 5 Routes : 5
Destination/mask Protocol Preference Cost Interface
0x010000/8 FSPF 20 100 Vfc10
0xfffc01/24 DIRECT 0 0 InLoop0
0xfffffa/24 DIRECT 0 0 InLoop0
0xfffffc/24 DIRECT 0 0 InLoop0
0xfffffd/24 DIRECT 0 0 InLoop0
The output shows that an FSPF route from Switch A to Switch C exists, with the outgoing interface
VFC 10.
# Display the node login information for VSAN 100.
[SwitchA] display fc login vsan 100
Interface VSAN FCID Node WWN Port WWN
Vfc1 100 0x020000 21:01:00:1b:32:a0:fa:12 21:01:00:1b:32:a0:fa:11
# Display the brief information about the name server database in VSAN 100.
[SwitchA] display fc name-service database vsan 100
VSAN 100:
FCID Type PWWN(vendor) FC4-type:feature
0x010000 0x01(N) 10:00:00:05:30:00:25:a3 SCSI-FCP:Target
0x020000 0x01(N) 21:01:00:1b:32:a0:fa:11 SCSI-FCP:Initiator
2. Display information for VSAN 200:
# Display the domain information of VSAN 200.
[SwitchA] display fc domain vsan 200
Domain Information of VSAN 200:
Running time information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1B:1B
Fabric name: 48:33:43:2d:46:43:1D:1D
Priority: 128
Domain ID: 2
Configuration information:
Domain configure: Enabled
Domain auto-reconfigure: Disabled
Fabric name: 48:33:43:2d:46:43:1B:1B
Priority: 128
Domain ID: 2 (preferred)
Principal switch running time information:
Priority: 1
Path Interface

Table of Contents

Other manuals for HP FlexFabric 5700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexFabric 5700 series and is the answer not in the manual?

HP FlexFabric 5700 series Specifications

General IconGeneral
Layer SupportL2/L3
Routing ProtocolOSPF, BGP, RIP, IS-IS, Static Routing
Remote Management ProtocolSNMP, CLI, Web
FeaturesVXLAN
Compliant StandardsIEEE 802.1D, 802.1Q, 802.1w, 802.1s, 802.3ad
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (non-condensing)
VLANs4K