65
[SwitchC-Vfc2] quit
# Configure Ten-GigabitEthernet 1/0/2 as a trunk port, and assign the port to VLAN 10.
[SwitchC] interface ten-gigabitethernet 1/0/2
[SwitchC-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchC-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10
[SwitchC-Ten-GigabitEthernet1/0/2] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchC] vlan 10
[SwitchC-vlan10] fcoe enable vsan 1
[SwitchC-vlan10] quit
# Configure two static routes in VSAN 1.
[SwitchC] vsan 1
[SwitchC-vsan1] fc route-static 010000 8 vfc 2
[SwitchC-vsan1] fc route-static 020000 8 vfc 2
Verifying the configuration
# Display the FC routing table in VSAN 1 on Switch A.
[SwitchA-vsan1] display fc routing-table vsan 1
Routing Table: VSAN 1
Destinations : 6 Routes : 6
Destination/mask Protocol Preference Cost Interface
0x020000/8 STATIC 10 0 Vfc1
0x030000/8 STATIC 10 0 Vfc1
0xfffc01/24 DIRECT 0 0 InLoop0
0xfffffa/24 DIRECT 0 0 InLoop0
0xfffffc/24 DIRECT 0 0 InLoop0
0xfffffd/24 DIRECT 0 0 InLoop0
# Display the FC routing table in VSAN 1 on Switch B.
[SwitchB-vsan1] display fc routing-table vsan 1
Routing Table: VSAN 1
Destinations : 6 Routes : 6
Destination/mask Protocol Preference Cost Interface
0x010000/8 STATIC 10 0 Vfc1
0x030000/8 STATIC 10 0 Vfc2
0xfffc02/24 DIRECT 0 0 InLoop0
0xfffffa/24 DIRECT 0 0 InLoop0
0xfffffc/24 DIRECT 0 0 InLoop0
0xfffffd/24 DIRECT 0 0 InLoop0
# Display the FC routing table in VSAN 1 on Switch C.
[SwitchC-vsan1] display fc routing-table vsan 1
Routing Table: VSAN 1
Destinations : 6 Routes : 6
Destination/mask Protocol Preference Cost Interface
0x010000/8 STATIC 10 0 Vfc2
0x020000/8 STATIC 10 0 Vfc2
0xfffc03/24 DIRECT 0 0 InLoop0
0xfffffa/24 DIRECT 0 0 InLoop0

Table of Contents