388
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Disable FIPS mode.
undo fips mode enable
By default, the FIPS mode is
disabled.
FIPS self-tests
To ensure the correct operation of cryptography modules, FIPS provides self-test mechanisms, including
power-up self-test and conditional self-test. You can also trigger a self-test. If the power-up self-test fails,
the device where the self-test process exists reboots. If the conditional self-test fails, the system outputs
self-test failure information.
NOTE:
If a self-test fails, contact HP Support.
Power-up self-tests
Power-up self-tests include the following types:
Known-answer test (KAT)
This test examines the availability of FIPS-allowed cryptographic algorithms. A cryptographic
algorithm is run on data for which the correct output is already known. The calculated output is
compared with the known answer. If they are not identical, the KAT test fails.
Pairwise conditional test (PWCT)
{ Signature and authentication test—The test is run when a DSA, RSA, or ECDSA asymmetrical
key pair is generated. It uses the private key to sign the specific data, and it then uses the public
key to authenticate the signed data. If the authentication is successful, the test succeeds.
{ Encryption and decryption test—The test is run when an RSA asymmetrical key pair is
generated. It uses the public key to encrypt a plain text, and it then uses the private key to
decrypt the encrypted text. If the decryption is successful, the test succeeds.
Table 19 li
sts the cryptographic algorithms examined by the power-up self-test.
Table 19 Power-up self-test list
T
yp
e O
p
erations
KAT
Tests the following algorithms:
SHA1, SHA224, SHA256, SHA384, and SHA512.
HMAC-SHA1, HMAC-SHA224, HMAC-SHA256, HMAC-SHA384, and
HMAC-SHA512.
AES.
RSA (signature and authentication).
DRBG.

Table of Contents

Other manuals for HP FlexFabric 5700 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexFabric 5700 series and is the answer not in the manual?

HP FlexFabric 5700 series Specifications

General IconGeneral
Layer SupportL2/L3
Routing ProtocolOSPF, BGP, RIP, IS-IS, Static Routing
Remote Management ProtocolSNMP, CLI, Web
FeaturesVXLAN
Compliant StandardsIEEE 802.1D, 802.1Q, 802.1w, 802.1s, 802.3ad
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (non-condensing)
VLANs4K