318 User Guide Integrated Lights-Out
GET_HOST_POWER_STATUS Parameters
None
GET_HOST_POWER_STATUS Runtime Errors
The possible GET_HOST_POWER_STATUS error messages include:
<RIBCL VERSION="2.0">
Host power is OFF.
Host power is ON.
GET_HOST_POWER_STATUS Return Messages
The following information is returned within the response:
<GET_HOST_POWER
HOST POWER="OFF"
/>
SET_HOST_POWER
The SET_HOST_POWER command is used to toggle the power button of
server. For this command to parse correctly, the SET_HOST_POWER command
must appear within a SERVER_INFO command block, and SERVER_INFO
MODE must be set to write. The user must have the virtual power and reset
privilege to execute this command.
Example:
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<SERVER_INFO MODE="write">
<SET_HOST_POWER HOST_POWER="Yes"/>
</SERVER_INFO>
</LOGIN>
</RIBCL>