11-37
Configuring Advanced Threat Protection
Using the Instrumentation Monitor
Viewing the Current Instrumentation Monitor
Configuration
The show instrumentation monitor configuration command displays the config-
ured thresholds for monitored parameters.
Figure 11-10. Viewing the Instrumentation Monitor Configuration
An alternate method of determining the current Instrumentation Monitor
configuration is to use the show run command. However, the show run com-
mand output does not display the threshold values for each limit set.
HP Switch# show instrumentation monitor configuration
PARAMETER LIMIT
------------------------- ---------------
mac-address-count 1000 (med)
ip-address-count 1000 (med)
system-resource-usage 50 (med)
system-delay 5 (high)
mac-moves/min 100 (med)
learn-discards/min 100 (med)
ip-port-scans/min 10 (med)
arp-requests/min 100 (low)
login-failures/min 10 (med)
port-auth-failures/min 10 (med)
SNMP trap generation for alerts: enabled