Table 1 Events requiring FRU replacements scenarios (continued)
Action RequiredSymptomFRUEvent ID
Replace on first occurrence.The supercapacitor pack is
nearing end-of-life.
Controller218
Replace on first occurrence.The indicated disk type is invalid
and is not enabled in the current
configuration.
HDD233
Replace on first occurrence.An enclosure management
processor (EMP) detected a
serious error.
Controller235
Replace the CompactFlash.A timeout occurs while flushing
the CompactFlash.
CompactFlash239
Replace the CompactFlash.The CompactFlash hardware
detected an error.
CompactFlash240
Replace the CompactFlash.The controller module's
CompactFlash card has failed.
CompactFlash242
Replace on first occurrence.The coin battery is not present
or is not properly seated or has
reached end-of-life.
Controller246
Replace the FRU indicated.The FRU ID SEEPROM for the
indicated FRU cannot be read.
Various247
FRU ID data might not be
programmed.
Verify the following:A temperature sensor on a
controller FRU detected an
Controller307
The system has two power supplies and both
are running correctly
over-temperature condition that
caused the controller to
shutdown.
The ambient temperature is not too warm. The
enclosure operating range is 5–40°C
(41°F–104°F)
Obstructions to airflow.
A module or blank plate resides in every module
slot in the enclosure
If none of these conditions apply, replace the
controller module that reported the error.
Replace on first occurrence.The indicated controller module
has failed. This event can be
Controller313
ignored for a single-controller
configuration.
To determine whether the FRU must be replaced,
see Verifying component failure in the component's
replacement instructions document.
The indicated FRU has failed or
is not operating correctly. This
event follows some other
FRU-specific event indicating a
problem.
Various314
Replace on first occurrence.A hardware failure occurred: XOR
error.
Controller318
Replace on first occurrence.The indicated available disk has
failed.
HDD319
Replace on first occurrence.Power-On Self-Test (POST)
diagnostics detected a hardware
error.
Controller442
Replace with an SFP that supports a later speed.The controller detected that the
configured host-port link speed
SFP455
6 Troubleshooting HPE MSA 1040/2040 Storage

Other manuals for HP MSA 2040

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSA 2040 and is the answer not in the manual?

HP MSA 2040 Specifications

General IconGeneral
BrandHP
ModelMSA 2040
CategoryStorage
LanguageEnglish

Related product manuals