EasyManua.ls Logo

HP MSA 2050 - User Manual

HP MSA 2050
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MSA 2050 User Guide
Firmware Version: VL100
Part Number: 723983-005
Published: June 2017
Edition: 1
Abstract
This document describes initial hardware setup for HPE MSA 2050 controller enclosures, and is intended for use by
storage system administrators familiar with servers and computer networks, network administration, storage system
installation and configuration, storage area network management, and relevant protocols.

Table of Contents

Questions and Answers

  • A
    Annette SummersAug 19, 2025
    What to do if HP MSA 2050 Storage enclosure does not initialize?
    • G
      greenekathrynAug 20, 2025
      If the HP Storage enclosure doesn't initialize, a few things could be the issue. First, perform a rescan. If that doesn't work, power cycle the system. Also, check that the power cord is properly connected and verify the power source. Finally, check the event log for any errors.
  • M
    Matthew RangelAug 21, 2025
    Why is the front panel Fault/Service Required LED amber on my HP MSA 2050 Storage enclosure?
    • A
      Andrew SmithAug 22, 2025
      If the front panel Fault/Service Required LED on your HP Storage enclosure is amber, it indicates a fault. Check the LEDs on the back of the controller enclosure to identify the source of the fault, whether it's a FRU or connection. Review the event log for specific details and follow any recommended actions. If you were installing an I/O module FRU, try removing and reinstalling it, then check the event log for errors. If the problem persists, isolate the fault and contact an authorized service provider for assistance, as replacement might be necessary.
  • F
    Frederick Durham DDSAug 25, 2025
    Why is the power supply Input Power Source LED off on my HP MSA 2050?
    • L
      Lee FigueroaAug 25, 2025
      If the Input Power Source LED on the HP Storage power supply is off, it means the power supply isn't getting enough power. Verify that the power cord is properly connected and check the power source. Also, check that the power supply FRU is firmly locked into position. Check the event log in the SMU for specific information and follow any recommended actions. If the problem continues, isolate the fault and contact an authorized service provider.
  • M
    Michael YoungAug 26, 2025
    What to do if Host Link Status LED is off on HP MSA 2050?
    • W
      William GriffinAug 26, 2025
      If the Host Link Status LED is off on a connected port of your HP Storage, the link is down. Check the cable connections and reseat them if needed. Inspect the cables for any damage, and replace them if necessary. Try swapping cables to see if the fault is due to a defective cable. Verify that the switch (if any) is working properly, and test with another port if possible. Ensure the HBA is fully seated and the PCI slot is powered on. Review the event logs in the SMU for specific fault indicators in a host data path component, and follow any recommended actions. If the issue persists, contact an authorized service provider.
  • J
    Jeanette AbbottAug 27, 2025
    What does it mean if the rear panel Fault/Service Required LED is amber on HP MSA 2050 Storage enclosure?
    • P
      Phillip DavisAug 27, 2025
      If the rear panel Fault/Service Required LED on the HP Storage enclosure is amber, it could indicate a hardware-controlled power-up error, a cache flush error, or a cache self-refresh error. Try restarting the controller from the other controller using the SMU or the CLI. If that doesn't fix it, remove the controller and reinsert it. If the problem persists, contact an authorized service provider for assistance, as the controller may need to be replaced.
  • C
    colemanchristinaAug 29, 2025
    Why is Expansion Port Status LED off on HP MSA 2050?
    • M
      Michael BurnsAug 29, 2025
      If the Expansion Port Status LED is off on a connected port of your HP Storage, the link is down. Check the cable connections and reseat if necessary. Inspect the cable for damage and replace it if needed. Swap cables to see if the fault is caused by a defective cable. Review the event logs in the SMU for indicators of a specific fault in a host data path component and follow any recommended actions. If the issue persists, contact an authorized service provider.
  • B
    Brooke CantrellAug 31, 2025
    Why is the Fault/UID LED blinking amber on my HP MSA 2050 disk drive?
    • M
      Ms. Kimberly Maynard DVMSep 1, 2025
      If the Fault/UID LED on the HP Storage disk drive module is blinking amber, it means the disk drive is offline, and a predictive failure alert may have been received for it. Check the event log for specific details regarding the fault. Isolate the fault and contact an authorized service provider for assistance.
  • G
    Gabrielle GoodmanSep 2, 2025
    Why is the rear panel FRU OK LED off on my HP MSA 2050 Storage enclosure?
    • D
      David BartlettSep 2, 2025
      If the rear panel FRU OK LED on the HP Storage enclosure is off, check that the controller module is fully inserted and latched in place, and that the enclosure is powered on. Also, check the event log for specific details regarding the failure.
  • K
    Kayla ShepardSep 4, 2025
    Why are both disk drive module LEDs off on my HP Storage?
    • C
      cynthia72Sep 5, 2025
      If both the Online/Activity and Fault/UID LEDs are off on the HP Storage disk drive module, it could mean there's no power, the disk is offline, or the disk isn't configured. Check that the disk drive is fully inserted and latched in place, and that the enclosure is powered on.
  • R
    Regina GreenSep 6, 2025
    How to fix invalid cabling connection on HP Storage?
    • R
      ronald73Sep 7, 2025
      If you have an invalid cabling connection on your HP Storage, verify the controller enclosure cabling and ensure you're using the proper cables. Check the cabling paths for host connections and ensure the cabling paths between replication ports and switches are visible to one another. Make sure cable connections are securely fastened. Inspect cables for damage and replace them if necessary.

Summary

Overview of HPE MSA 2050 Storage System

HPE MSA 2050 Components

Installing HPE MSA 2050 Enclosures

Installation Checklist

Outlines sequential steps for installing enclosures and initial system configuration.

Connecting Controller and Drive Enclosures

Explains SAS cabling options, including straight-through and fault-tolerant configurations.

Powering On and Off Enclosures

Details the correct sequence for powering enclosures on and off, including AC/DC differences.

Connecting Hosts to HPE MSA 2050

Host System Requirements

Lists requirements for data hosts, including operating systems and multi-pathing support.

Connecting Enclosures to Data Hosts

Describes how to connect servers to storage ports using various cabling configurations.

Remote Snap Replication Setup

Details setting up Remote Snap replication between two storage systems.

Connecting to the Controller CLI Port

IP Address Configuration

Covers methods for obtaining and setting IP addresses via DHCP or CLI.

Basic Operation of HPE MSA 2050

Accessing the SMU

Instructions on accessing the web-based Storage Management Utility (SMU).

Configuring and Provisioning the Storage System

Guides on using the SMU to configure and provision the storage system and set up replication.

Troubleshooting HPE MSA 2050

Fault Isolation Methodology

Presents the basic methodology for locating faults and identifying Field Replaceable Units (FRUs).

Controller Failure Scenarios

Discusses cache behavior and data protection during controller failure events.

Isolating Host-Side Connection Faults

Provides procedures for troubleshooting connection faults between hosts and controller ports.

Isolating Controller Module Expansion Port Faults

Details troubleshooting steps for faults in controller module expansion port connections.

Isolating Remote Snap Replication Faults

Covers troubleshooting common issues encountered with Remote Snap replication setup.

Resolving Voltage and Temperature Warnings

Guides on addressing voltage and temperature warnings by checking fans and sensors.

Enclosure Front Panel LED Diagnostics

Details how to interpret front panel LED statuses to diagnose faults.

Disk Drive Module LED Diagnostics

Details how to interpret disk drive LED statuses to diagnose faults.

Host Port LED Diagnostics

Details how to interpret host port LED statuses to diagnose faults.

Power Supply LED Diagnostics

Details how to interpret power supply LED statuses to diagnose faults.

HPE MSA 2050 LED Descriptions

MSA 2050 SAN Controller Module Rear Panel LEDs

Explains the LEDs on the rear panel of SAN controller modules for FC and iSCSI ports.

Specifications and Requirements

Safety Requirements

Emphasizes adherence to local safety codes and equipment markings for installation.

Electrostatic Discharge (ESD) Prevention

HP MSA 2050 Specifications

General IconGeneral
ModelHP MSA 2050
CategoryStorage
Controller TypeDual Controller
Form Factor2U
Maximum Drives Supported192
Cache Memory8 GB per controller
Number of Controllers2
ProtocolsFibre Channel, iSCSI, SAS
Drive Support2.5-inch SFF and 3.5-inch LFF drives
Host Interfaces16 Gb Fibre Channel, 10GbE iSCSI, 12 Gb SAS
RAID Levels SupportedRAID 0, 1, 5, 6, 10
Expansion OptionsSupports expansion with MSA 2050 LFF and SFF Disk Enclosures
Power SuppliesDual, redundant power supplies
Operating Temperature10°C to 35°C (50°F to 95°F)
Warranty3 years
Maximum Raw Capacity192 TB