EasyManua.ls Logo

HP MSA 2050 - MSA 2050 Array SFF or Supported 24-Drive Expansion Enclosure; Leds: MSA 2050 Array SFF or Supported 24-Drive Expansion Enclosure: Front Panel

HP MSA 2050
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Front panel LEDs 63
Enclosure bezel removal
TIP: Please refer to Figure 25 (bezel front) and Figure 26 (bezel back) on page 62 before removing the bezel from the
enclosure front panel.
You may need to remove the bezel to access front panel components such as disk drive modules and ear kits. Although
disk module LEDs are not visible when the bezel is attached, you can monitor disk behavior from the management
interfaces (see “Fault isolation methodology” (page 44) for more information about using LEDs together with event
notification, the CLI, and the SMU for managing the storage system).
While facing the front of the enclosure, grasp the left and right ear covers, such that your fingers cup the bottom of each
ear cover, with thumb at the top of each cover. Gently pull the top of the bezel while applying slight inward pressure
below, to release the bezel from the ball studs.
NOTE: The bezel should be attached to the enclosure during operation to protect ear circuitry. To reattach the bezel to
the enclosure front panel, follow the instructions provided in “Enclosure bezel attachment” (page 62).
MSA 2050 Array SFF or supported 24-drive expansion enclosure
Figure 27 LEDs: MSA 2050 Array SFF or supported 24-drive expansion enclosure: front panel
LED Description Definition
1 Enclosure ID Green — On
Enables you to correlate the enclosure with logical views presented by
management software. Sequential enclosure ID numbering of controller
enclosures begins with the integer 1. The enclosure ID for an attached drive
enclosure is nonzero.
2 Disk drive Online/Activity See “Disk drive LEDs” (page 65).
3 Disk drive Fault/UID See “Disk drive LEDs” (page 65).
4 Unit Identification (UID) Blue — Identified.
Off — Identity LED off.
5 Heartbeat Green — The enclosure is powered on with at least one power supply
operating normally.
Off — Both power supplies are off; the system is powered off.
6 Fault ID Amber — Fault condition exists. The event has been identified, but the
problem needs attention.
Off — No fault condition exists.

Table of Contents