Page #51 background image
4-7
Troubleshooting
Diagnosing with the LEDs
Troubleshooting
The port may be
improperly
configured, or
the port may be in
a “blocking”
state by the
normal operation
of the Spanning
Tree, LACP, or
IGMP features.
Use the switch console to see if the port is part of a dynamic trunk (through the LACP
feature) or to see if Spanning Tree is enabled on the switch, and to see if the port may
have been put into a “blocking” state by those features. The show lacp command displays
the port status for the LACP feature; the show spanning-tree command displays the port
status for Spanning Tree.
Also check the Port Status screen using the show interfaces command to see if the port
has been configured as “disabled”.
Other switch features that may affect the port operation include VLANs and IGMP. Use
the switch console to see how the port is configured for these features.
For software troubleshooting tips, see the chapter “Troubleshooting” in the Management
and Configuration Guide, which is on the Documentation CD-ROM that came with your
switch.
Make sure also, that the device at the other end of the connection is indicating a good
link to the switch. If it is not, the problem may be with the cabling between the devices or
the connectors on the cable.
Tip Problem Solution

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing