Hardware options installation 101
Cable Description
Connection to SAS
expander
Connection to drive bay
781579-001
4 x4 mini-SAS cable Port 5
Port 6
Port 7
Port 8
8 SFF Bay 2 Port 1
8 SFF Bay 2 Port 2
8 SFF Bay 3 Port 1
8 SFF Bay 3 Port 2
o Group DSAS expander card to rear drive cage
Cable Description
Connection to SAS
expander
Connection to drive bay
776401-001
X4 mini-SAS cable Port 9 2SFF/3LFF
HP 12G SAS Expander Card ports
To install the component:
1. Power down the server (on page 24).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 24).
o Remove the server from the rack (on page 25).
4. Remove the access panel (on page 25).
5. Remove the air baffle (on page 31).
6. Remove the fan cage (on page 27).
7. Remove the primary PCI riser cage.
IMPORTANT: The HP 12G SAS Expander Card is not supported in the secondary PCI riser cage.