Hardware options installation 107
The cabling is the same for both backplanes. In the following illustration, the two-bay SFF rear cage
backplane is shown.
14. Install the air baffle.
15. Install the fan cage.
16. Install the access panel (on page 26).
17. Install the server into the rack ("Installing the server into the rack" on page 36).
18. Connect each power cord to the server.
19. Connect each power cord to the power source.
20. Power up the server (on page 24).
HP Flexible Smart Array Controller
CAUTION: HP recommends performing a complete backup of all server data before performing
a controller or adapter installation or removal.
Before installing the controller, observe the following requirements:
• To ensure cables are connected correctly, observe the labels on the cable and component connectors.
• Be sure you have the latest firmware for the controllers, HBAs, and the expander card. To download the
latest firmware, see the HP website (http://www.hp.com/go/hpsc).
To install the component:
1. Power down the server (on page 24).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following: