EasyManua.ls Logo

HP ProLiant DL380 Gen9 - Removing an Expansion Slot Blank

HP ProLiant DL380 Gen9
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and replacement procedures 54
8.
Remove the screw securing the Systems Insight Display, and then remove the Systems Insight
Display.
To replace the component, reverse the removal procedure.
Removing an expansion slot blank
WARNING:
To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some
internal circuitry remain active until AC power is removed.
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.
To remove the component:
1. Power down the server (on page 27).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 27).
o Remove the server from the rack (on page 28).
4. Remove the access panel ("Access panel" on page 32).
5. Remove the PCIe riser cage:
o Primary PCIe riser cage (on page 34)
o Secondary PCIe riser cage (on page 35)
6. Remove the expansion slot blank:

Table of Contents

Other manuals for HP ProLiant DL380 Gen9

Related product manuals