Component identification 92
DIMM slot locations
DIMM slots are numbered sequentially (1 through 12) for each processor. The supported AMP modes use
the letter assignments for population guidelines.
Hot-plug fans
CAUTION: To avoid damage to server components, fan blanks must be
installed in fan bays
1 and 2 in a single-processor configuration.
CAUTION: To avoid damage to the equipment, do not operate the server for extended
periods of time if the server does not have the optimal number of fans installed. Although the
server might boot, Hewlett Packard Enterprise does not recommend operating the server
without the required fans installed and operating.
Valid fan configurations are listed in the following table.
Configuration
Fan bay 1
Fan bay 2
Fan bay 3
Fan bay 4
Fan bay 5
Fan bay 6
1 processor
Fan blank
Fan blank
Fan
Fan
Fan
Fan
1 processor, 24 SFF or
12 LFF configuration
with high-performance
fans
Fan
Fan
Fan
Fan
Fan
Fan
2 processors
Fan
Fan
Fan
Fan
Fan
Fan