EasyManua.ls Logo

HP ProLiant ML110 Gen9 - Storage Controller Installation Guidelines; Installing the Storage Controller and FBWC Module Options

HP ProLiant ML110 Gen9
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware options installation 49
CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove
the battery pack while an array capacity expansion, RAID level migration, or stripe size migration
is in progress.
CAUTION:
After the server is powered down, wait for 30 seconds, and then check the amber LED
before unplugging the cable from the cache module. If the amber LED flashes after 30 seconds,
do not remove the cable from the cache module. The cache module is backing up data. Data will
be lost if the cable is detached when the amber LED is still flashing.
Storage controller installation guidelines
To maintain optimal thermal conditions when installing an HP P-series Smart Array Controller or an HP HBA
option, HP recommends the following guidelines.
Install this storage
controller/HBA option
In slot Using this cable option
H240 adapter
Slot 3 or Slot 5 HP Host Bus Adapter
Mini-SAS cable option
P440 controller
Slot 3 or Slot 5 HP Smart Array Controller
Mini-SAS cable option
P840 controller
Slot 3 or Slot 5 HP Smart Array Controller
Mini-SAS cable option
Installing the storage controller and FBWC module options
To install the component:
1. Power down the server (on page 18).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Place the server on its side.
4. Remove the access panel (on page 18).
5. If installed, remove the PCI air baffle (on page 22).
6. Remove the system air baffle (on page 23).
7. If you intend to use an FBWC module, install the module on the storage controller.

Table of Contents

Other manuals for HP ProLiant ML110 Gen9

Related product manuals