Removal and replacement procedures 62
System fans
The server includes four system fan assemblies; three front fan holder assemblies and a rear fan
assembly.
Fan holder assembly removal and replacement
To remove the front fan/PCI card holder assembly :
1. Power down the server.
2. Disconnect th e p ower cord(s).
3. Unlock the server if necessary and remove t h e access panel as described in the sect ion ā€œSystem
covers .ā€
4. Remove all full-size ex pansion cards as described in the section ā€œRemoving an expansion cardā€
if necessary .
5. On the front fan holder assembly, press the thumb lever down slightly (Figure 3-40 , 1) and slide
the assembly a short distance toward the top o f the server chassis (Figure 3-40, 2).
Figure 3-40 Removing the front fan/PCI card holder assembly
6. Rotate the fan assembly toward the rear of the chassis and lift away from the mounting slots, but
not completely from the chassis.
7. While supporting the fan holder assembly with one hand, disconnect the fan cable from system
board connector (Figure 3-40, 3).
8. Remove the front fan holder assembly from the chassis.
End of procedure.