Removal and replacement procedures 64
3.
Unlock the server if necessary and remove t h e access panel as described in the sect ionSystem
covers .”
4. Remove the a ir baffle as described in the sect i onRemoving a processor.”
5. Remove the two screws (Figure 3-43, 1) and take off the rear f an (Figure 3-43, 2).
WARNING: Be sure to support the fan with your hands when removing it from the chassis. The fan
could fall and cause personal injury or equipment damage if not supported.
6. Disconnect the fan cable from the system board connector (Figure 3-43, 3).
Figure 3-383 Removing the rear chassis fan assembly
7. Lift the fan assembly away from the rear panel and from the chassis.