Table 8 Storage Management Provider errors (continued)
Recommended actionError messageError code
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get the associated pool for the LUN from
cache.
0x25005017
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to update disk in cache.0x25005018
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get the disk from the controller.0x25005019
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get associated disks for the LUN from
cache.
0x2500501A
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get associated disks for the pool from
cache.
0x2500501B
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache
Unknown type of storage object.0x2000501C
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Unknown type of storage object.0x2500501C
Restart Storage Management Service.Failed to get the associated subsystem for the
storage object from cache.
0x2400501D
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get the associated subsystem for the
storage object from cache.
0x2500501D
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get the storage object from cache.0x2500501E
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to update the storage object in cache.0x2500501F
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get the storage object from the controller.0x25005020
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to copy storage objects.0x25005021
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache
Error creating Pool.0x20005022
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache
Error deleting LUN.0x20005023
The storage contains0x20005024
Failed to delete the reserved LUN.0x20005025
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Failed to get the logical drive from the controller.0x25005026
160 Troubleshooting, servicing, and maintenance