Power fault LEDs
The following table provides a list of power fault LEDs and the subsystems that are affected. Not
all power faults are used by all servers.
LED behaviorSubsystem
1 flashSystem board
2 flashesProcessor
3 flashesMemory
4 flashesRiser board PCIe slots
5 flashesFlexibleLOM
6 flashesRemovable HPE Flexible Smart Array controller/Smart
SAS HBA controller
7 flashesSystem board PCIe slots
8 flashesPower backplane or storage backplane
9 flashesPower supply
Front drive thermal LED
The thermal warning function of the front drive health/thermal LED depends on the iLO 08-HD
Max sensor reading. This function is disabled under these conditions:
There are no drives in the front drive cages 1 and 2.
The temperature sensor in one or more front drives has failed.
Under these conditions, iLO shows the 08-HD Max sensor reading as N/A. To view temperature
sensor data, log in to iLO 4 web interface and navigate to the InformationSystem
InformationTemperatures.
If the 08-HD Max sensor reading shows N/A, observe the following when extending the front
drive cage:
Do not keep the drive cages out of the chassis for more than 140 sec.
Keep the drive cages inside the chassis for at least 300 sec before extending them out again.
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing
a health event. Combinations of illuminated Systems Insight Display LEDs, the system power
LED, and the health LED indicate system status.
Table 1 Systems Insight Display LEDs and internal health LED combinations
StatusSystem power
LED
Health LEDSystems Insight
Display LED and
color
One or more of the following conditions might exist:AmberRedProcessor
(amber)
Processor in socket X has failed.
Processor X is not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during POST.
Processor in socket X is in a pre-failure condition.GreenAmber