Table 31 Main error codes (continued)
Details and solutionDescriptionError code
This error can occur is an attempt is made to
upgrade a drive with the wrong personality or
version for that drive.
Firmware upgrade errorD7
Ensure that the correct drive firmware is
being used to update the drive.
If the correct drive firmware is being used,
update the library firmware.
Power cycle the device and attempt the
operation again.
Power-cycle the unit.Library controller data base errorD8
No SCSI IC detectedD9
When running the wellness test, the bar code
did not match the previous value for that tape
DA
Check the bar code label for proper
application and damage.
Run the wellness test again.
I2C Bus failure.DC
Power-cycle the device.
On the MSL4048, MSL8048, and MSL8096,
power off the library and re-seat the library
controller from the back panel.
Incompatible magazine detected. The mailslot
was enabled with a different mailslot magazine
E0
Either replace the lower left magazine with
the original magazine, or disable and
type than is currently in the library. For example,
re-enable the mailslot to reconfigure the
the mailslot was enabled with a three-slot
library with the new mailslot configuration.
mailslot magazine and then the lower-left
162 Troubleshooting