b. On the Virtual Uplink Port tab page, set the filter criteria to display the required
virtual upstream ports.
c. In the information list, right-click and choose Add from the shortcut menu.
d. In the dialog box that is displayed, set the parameters.
VLAN ID: 1000
Frame: 0
Slot: 19
Port: 0
e. Click Done.
5. Configure a program profile on the OLT side.
a. Choose Configuration > Access Profile Management from the main menu. In
the dialog box that is displayed, choose IGMP Profile from the navigation tree.
b. Click the Program Profile tab, and select the required device type from the
Device Type drop-down list.
c. Right-click and choose Add Global Profile from the shortcut menu.
d. In the dialog box that is displayed, set the parameters.
Name: program1
Start IP Address: 224.0.1.1 (IP address of the multicast program)
End IP Address: 224.0.1.1
Source IP Address: 10.10.10.20 (IP address of the multicast server)
Preview Profile: 0 (the default value)
EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual 3 Configuration
Issue 02 (2011-12-08) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
122

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei EchoLife HG8110 and is the answer not in the manual?

Huawei EchoLife HG8110 Specifications

General IconGeneral
BrandHuawei
ModelEchoLife HG8110
CategoryTouch terminals
LanguageEnglish

Related product manuals