2.3.6 Memory Protection Technologies
The following memory protection technologies are supported:
l ECC
l Full mirroring
l Address range mirroring
l Rank sparing mode
l Faulty DIMM isolation
l Memory thermal throttling
l Memory address parity protection
l Adaptive double device data correction (ADDDC)
l Memory demand/patrol scrubbing
l Data scrambling
l ADDDC+1
2.4 Storage
2.4.1 Drive Configurations
Table 2-4 Drive configurations
Configuration
Maximum Drives Drive Management
Mode
Front drives
a
2
b
l Slots 0 and 2 support
SAS/SATA/NVMe
drives.
l M.2 FRUs can be
installed only in slots 0
to 3.
1 x RAID controller card
l a: Only 2.5-inch drives fit into the front slots.
l b: Mixed configuration of M.2 modules and SAS/SATA/NVMe drives is supported.
l Contact your local Huawei sales representative or use the Intelligent Computing
Compatibility Checker to determine the components to be used.
2.4.2 Drive Numbering
l SAS/SATA/NVMe drives
FusionServer Pro CH121 V5 Compute Node