M.2 FRU Indicators
Figure 2-13 M.2 FRU indicators
Table 2-6 M.2 FRU indicator description
Indicator
Description
M.2 FRU fault indicator
l Off: The M.2 FRU is running properly.
l Blinking yellow: The M.2 FRU is being located, or RAID
is being rebuilt.
l Steady yellow: The M.2 FRU is faulty or not detected.
M.2 FRU activity
indicator
l Off: The M.2 FRU is not in position or is faulty.
l Blinking green: Data is being read, written, or
synchronized.
l Steady green: The M.2 FRU is inactive.
NVMe SSD Indicators
Figure 2-14 NVMe SSD indicators
l If the VMD function is enabled and the latest Intel RSTe driver is installed, NVMe SSDs
support surprise hot swap.
Table 2-7 NVMe SSD indicators (VMD enabled)
Green Indicator
Yellow Indicator Description
Off Off The NVMe SSD cannot be detected.
Steady green Off The NVMe SSD is working properly.
Blinking green at 2
Hz
Off Data is being read from or written to the
NVMe SSD.
Off Blinking yellow at
2 Hz
The NVMe SSD is being located.