Installation Manual 
Quidway S3000-EI Series Ethernet Switches
  Chapter 3  Installation
 
3-5 
3.2.4  Connect Ground Wire 
 
  Caution: 
The correct connection of the switch ground wire is the primary guarantee for the lightning protection 
and anti-interference requirement for a switch. So the ground wire should be connected carefully. 
 
The power input end of the switch is connected with a noise filter, whose central 
ground is directly connected to the chassis, forming the so-called chassis ground 
(also called PE). This chassis must be well grounded so that the faradism and 
leakage electricity can be safely released to the ground to enhance the switch 
capability of withstanding electromagnetic interference.   The switch should be 
grounded in the following way.   
  If there is grounding strip in the Ethernet switch installation environment, attach 
one end of the yellow-green protection ground wire to the grounding screw of the 
grounding strip and fasten the captive nuts.   Note that the fire main and 
lightning rod of a building are not suitable for grounding the switch. The ground 
wire of a switch shall be connected to the grounding device of the equipment 
room. 
Power input
Ethernet Switch
Grounding strip
Grounding wire
Grounding screw
Power input
Ethernet Switch
Grounding strip
Grounding 
Grounding screw
Power input
Ethernet Switch
Grounding strip
Grounding wire
Grounding screw
Power input
Ethernet Switch
Grounding strip
Grounding 
Grounding screw
Power input
Ethernet Switch
Grounding strip
Grounding wire
Grounding screw
Power input
Ethernet Switch
Grounding strip
Grounding 
Grounding screw
Power input
Ethernet Switch
Grounding strip
Grounding wire
Grounding screw
Power input
Ethernet Switch
Grounding strip
Grounding 
Grounding screw
 
Figure 3-5 Sketch of grounding with grounding strip available   
  If there is no grounding strip but earth nearby and the grounding body is allowed 
to be buried, you can simply hammer an angle iron or steel pipe no shorter than 
0.5m into the earth.  In this case, the yellow-green protection ground wire 
should be welded with the angle iron (steel pipe) and the joint should be 
processed against eroding.