EasyManua.ls Logo

Huawei Quidway S3000-EI Series - Module Panel and the Indicators; Module Interface Fiber; 1000 Base-LX GL Module (40 Km)

Huawei Quidway S3000-EI Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Manual
Quidway S3000-EI Series Ethernet Switches
Chapter 7 Optional Interface Modules
7-4
7.2.1 Module Panel and the Indicators
1000Base-ZX module panel is illustrated in the following figure.
1000BASE-ZX
GZ MODULE
Class 1 Laser Product
LINK
ACTIVE
TX RX
Figure 7-3 1000Base-ZX module panel
The descriptions of panel indicators are as follows:
Table 7-3 Meaning of indicators on 1000Base-ZX module panel
Indicator Status description
LINK Off means that the line is disconnected. On means the line is connected.
ACTIVE Off means that no data is being received or sent. Blinking means data is being received or sent.
7.2.2 Module Interface Fiber
1000Base-ZX module interface matches LC connector.
Figure 7-4 LC connector
The following table describes the interface attributes of 1000Base-ZX module.
Table 7-4 1000Base-ZX module attributes
Attribute Description
Connector
LC
Number of connectors
1
Transmission medium and
maximum transmission distance
9/125µm Single Mode optical fiber with a maximum transmission distance
of 70km.
Compliant standard
IEEE 802.3 z
Central wavelength
1550nm
Transmitting optical power
-3.0dBm to 2.0dBm
Receiving sensitivity
-23dBm
7.3 1000Base-LX GL Module (40km)

Table of Contents