1. The place about 0.5 to 1 meter (1.64 ft to 3.28 ft) away from the cable entry of equipment room or outdoor
cabinet
2. The place on the roof edge about one meter (3.28 ft) away from the turning point of the wiring ladder
3. Optional: The middle point of the cable (when the cable is longer than 60 meters(196.85 ft))
4. Optional: The place on the roof edge about one meter away from the turning point of the wiring ladder
(when the horizontal portion of the cable on the roof-top is longer than 30 meters(98.42 ft))
5. Optional: The middle point of the horizontal portion of the cable (when the horizontal portion on the roof-top is
longer than 60 meters (196.85 ft))
Grounding the IF Cable
a
Grounding points of the IF cable
The grounding point depends on the installation mode and the length of the IF cable. Generally, the IF cable
should be grounded to a minimum of three points. When the IF cable is longer than 60 meters (196.85 ft), add a
grounding point for every extra 30 meters(98.42 ft).
As recommended in ITU K.56, the IF cable does not need to be separately grounded under the ODU,if the
ODU is properly grounded. The IF cable is grounded through the ODU.