46
Body of the
connector
Rotating to tighten
the lock nut
Fixing the
connector
4. Stripping off the dielectric
insulating layer
5. Installing the body of the
connector
Installing the IF Cable
Appendix
Terminating the IF Cable with the N Connectors
1. Stripping off the cable sheath
2. Gliding the lock nut and clamp 1
3. Folding back the braided shield to cover clamp
1, and binding the braided shield by using clamp 2
16 mm
(0.63 inch)
Lock nut
Clamp 1
Clamp 2
Cutting off the redundant part of
the shielding layer
6 mm
(0.24 in.)
0.5 mm
(0.02 inch)
Filing the core wire head into
an arc shape
15 N·m
(132.76 lbf.in.)