47
1. Stripping off the cable sheath
2. Gliding the lock nut and clamp 1 over the
cable
3. Folding back the braided shield to cover clamp 1,
and binding the braided shield by using clamp 2
4. Stripping off the dielectric insulating layer
5. Installing the body of the connector
Terminating the IF Cable with the TNC Connectors
16 mm
(0.63 inch)
Lock nut
Clamp 1
Clamp 2
Cutting off the redundant
part of the shielding layer
6 mm
(0.24 inch)
0.5 mm
(0.02 inch)
Filing the core wire head
into an arc shape
Body of the connector
Rotating to tighten
the lock nut
Fixing the connector
15 N·m
(132.76 lbf.in.)