HUAWEI SE2900 Session Border Controller
Hardware Description
1 Service Processing Device
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Table 1-14 F8002 subrack technical specifications
Mechanical
specificatio
ns
130.5 mm x 442.0 mm x 675.0 mm (5.14 in. x
17.40 in. x 26.57 in.)
Weight of an empty
subrack
NOTE
An empty subrack is equipped with two fan trays
and two AC PSUs.
Weight of a fully loaded
subrack
47.8 kg (105.38 lb)
NOTE
A fully loaded subrack is equipped with two fan
trays, two AC PSUs, two MXUA0s, and four
SPUA0s.
High-voltage DC: 192 V to 288 V
2000 W (The rated power of each AC PSU is
2000 W)
NOTE
The subrack is configured with two AC PSUs in 1+1
redundancy mode.
Environme
ntal
specificatio
ns
Operating temperature: 0°C to 40°C (32°F
to 104°F)
Storage temperature: -40°C to +70°C
(-40°F to +158°F)
Long-term operating humidity: 5% RH to
85% RH (non-condensing)
Short-term operating humidity: 5% RH to
95% RH (non-condensing)
Storage humidity: 10% RH to 95% RH
(non-condensing)
-60 m to +4000 m (-196.85 ft to +13123.20 ft)
Short term means that the consecutive working period is not more than 96 hours and that the cumulative
working period over a year is not more than 15 days.