HUAWEI SE2900 Session Border Controller
Hardware Description
1 Service Processing Device
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Long-term operating humidity: 5% RH to
85% RH (non-condensing)
Short-term operating humidity: 5% RH to
95% RH (non-condensing)
Storage humidity: 10% RH to 95% RH
(non-condensing)
-60 m to +4000 m (-196.85 ft to +13123.20 ft)
Short term means that the consecutive working period is not more than 96 hours and that the cumulative
working period over a year is not more than 15 days.
1.3.1 PEM
Functions
Table 1-5 describes the functions of the power entry module (PEM).
Table 1-5 PEM functions
Supplies power to devices in the subrack.
Supports wide input voltage range.
Power
distribution
monitoring
Detects the installation status and type of PEMs.
Provides the indicators on the panel to indicate PEM status.
Detects the voltage and power of the subrack.
Detects the status of the circuit breakers and surge protection circuits.
Detects the PEM temperature.
Reports voltage, current, and power information in real time.
Implements the electronic label function.
Implements surge protection, short circuit protection, and
over-current protection.
Prevents incorrect insertion.
Appearance
Figure 1-10 shows a PEM.