Loading...
Recommended: Communications cable with a conductor cross-sectional area
of 1 mm
2
and a cable outer diameter of 14–18 mm.
RJ45 network port connection
Recommended: CAT 5E outdoor shielded network cable with an outer
diameter less than 9 mm and internal resistance no greater than 1.5 ohms/10
m, with a shielded RJ45 connector.
NO TE
Select only one installation mode in practice. Terminal block connection is
recommended.
COM1, COM2, and COM3 are holes for communications and power cables of the
tracking system.
NO TICE
When laying out communications cables, separate them from power cables to
avoid strong signal interference sources.
5.6.2.1 Terminal Block Connection
Terminal Block Port Denitions
Figure 5-24 shows an RS485 terminal block.
Figure 5-24 Terminal block
SUN2000-(50KTL, 60KTL, 65KTL)-M0
User Manual 5 Electrical Connections
Issue 11 (2024-02-02) Copyright © Huawei Technologies Co., Ltd. 62