Parameter Name Description
High feed-in power duration threshold for
triggering inverter shutdown (s)
The default value is 20. This
parameter species the duration
threshold of high feed-in power for
triggering inverter shutdown.
When High feed-in power
duration threshold for triggering
inverter shutdown is set to 5,
Shutdown at high feed-in power
takes precedence.
When High feed-in power
duration threshold for triggering
inverter shutdown is set to 20,
Grid connection with limited
power takes precedence (when
Active power control is set to
Grid connection with limited
power).
Note a: This parameter is supported only for the AS4777 grid code.
----End
7.2.1.2 Apparent Power Control on the Inverter Output Side
On the home screen, tap Settings > Power adjustment to set inverter
parameters.
Figure 7-12 Apparent power control
SUN2000-(3KTL-10KTL)-M1 Series
User Manual 7 Man-Machine Interaction
Issue 17 (2024-01-12) Copyright © Huawei Technologies Co., Ltd. 93

Table of Contents

Other manuals for Huawei SUN2000-6KTL-M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-6KTL-M1 and is the answer not in the manual?

Huawei SUN2000-6KTL-M1 Specifications

General IconGeneral
Max. Efficiency98.4%
Rated AC Output Power6000 W
Max. AC Apparent Power6600 VA
AC Grid Frequency50/60 Hz
Dimensions525 x 470 x 146.5 mm
Weight17 kg
Operating Temperature Range-25°C to +60°C
IP RatingIP65
Max. DC Voltage1100 V
Start Voltage200 V
European Weighted Efficiency97.8%
Cooling MethodNatural Convection
Max. DC Power9000 W
Nominal Output Voltage230 V

Related product manuals