Programmable Rain Off
This feature permits the user to stop all pro-
grammed waterings for a designated period from
1 to 7 days. At the end of the programmable rain
off period, the controller will resume normal
automatic operation.
1. Turn the dial to the SYSTEM OFF position.
Wait for OFF to be displayed.
2. Press
as many times as needed to set
the number of days off desired (up to 7).
3. Turn the dial back to the AUTOMATIC position at
which time, OFF, a number and the DAYS icon
all remain on.
The days off remaining will decrease at midnight
of each day. When it goes to zero, the display will
show the normal time of day and normal irrigation
will resume at the next scheduled start time.
Bypass Weather Sensor
If the weather sensor is interrupting irrigation, you can bypass it by
using the manual watering options described below. The dial positions
MANUAL-ONE STATION and position MANUAL-ALL STATIONS as well
as the One Touch Start and Advance process will successfully bypass
the rain sensor.
Seasonal Adjustment
Seasonal Adjust is used to make global run time changes without
re-programming the entire controller. To use the seasonal adjustment
feature:
1. Turn the dial to the SEASONAL
ADJUSTMENT position.
2. The display will now show a flashing number followed by a %, as
well as the bar graph which always remains on the display. Press
the or buttons to adjust the percentage of the seasonal ad-
justment. Each bar on the graph represents 10%. This feature can
adjust the controller from 10% to 150% of the original program.
To view the new adjusted run times, simply turn the rotary dial to
the SET STATION RUN TIMES position, the displayed run time will be
updated accordingly as the seasonal adjustment is made.
NOTE: The controller should always be initially pro-
grammed in the 100% position.
Manually Run a Single Station
1. Turn dial to the MANUAL-ONE STATION position.
2. Station run time will flash in the display. Use the
button to
move to the desired station. You may use the or button to
select the amount of time for a station to water.
3. Turn the dial clockwise to the AUTOMATIC position to run the sta
-
tion (only the designated station will water, then the controller will
return to automatic mode with no change
in the previously set program). Also see
One Touch Manual Start and Advance on
page 10.
Manually Run All Stations
1. Turn dial to MANUAL-ALL STATIONS.
2. Select program A, B, or C by pressing the button.
3. Press the
button until desired starting station is displayed.
4. Station run time will flash in the display. Use the
or button
to select the amount of run time for the station to water if different
from the run time displayed.
5. Use the
button to move to the next station.
6. Repeat steps 3 and 4 to customize
each station if desired.
7. Press the
button until you reach the
station that you would like watering to begin.
9