EasyManua.ls Logo

Hunter EC

Hunter EC
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENG
TROUBLESHOOTING GUIDE (cont.)
PROBLEM CAUSES SOLUTIONS
Automatic irrigation does not start at
start time and controller is not in the
system off mode.
AM/PM of time of day not set correctly.
AM/PM of start time not set correctly.
Start time is disabled (Set for Off).
Controller is not receiving AC power.
Correct AM/PM of time of day.
Correct AM/PM of start time. Set start time.
See “Setting Watering Start Times”.
Check AC connections.
Controller waters the same area
more than one time/Controller cycles
continuously.
Too many start times entered in program
(user error).
One start time activates a complete cycle.
See “Setting Watering Start Times”.
SPECIFICATIONS
Operating Specifications
Station Run Time: 0 to 4 hours in 1-minute increments.
Start Times: 4 per day, per program, for up to 12 daily starts.
Watering Schedule: 7-day calendar or interval (1 to 31 day)
programming.
AM/PM or 24 hour clock option.
Start time stacking.
Simple manual operation, including 1 button manual operation.
Seasonal Adjustment: 10 to 150% in 10% increments.
Electrical Specifications
Transformer Input: 230/240VAC, 50/60Hz International Use.
Transformer Output: 24VAC, 0.625 Amps.
Station Output: 24VAC, .28 Amps per station.
Maximum Output: 24VAC, .56 Amps.
Master Valve Output: 24VAC, .28 Amps.
Battery: Not required for program backup. 9-volt alkaline battery
(not included) may be used to program controller in absence of
AC power.
Electronic short circuit protection.
Surge protection: primary MOV-type.
Non-volatile memory for program data.
Controller will track time for 4 weeks in event of a power outage
(even without a 9 volt battery).
Rain sensor override by manual operation.
12