EasyManua.ls Logo

Huntleigh Sonicaid Team 3 Series - User Manual

Huntleigh Sonicaid Team 3 Series
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Team 3

Table of Contents

Questions and Answers

  • D
    deniseanthonyAug 18, 2025
    What to do if no signal appears when the oximetry sensor is connected to Huntleigh Measuring Instruments?
    • J
      Jessica MolinaAug 18, 2025
      If the oximetry sensor is connected to the Huntleigh Measuring Instruments and no signal appears, or the signal disappears after some monitoring time, ensure the connector jack is properly inserted. Also, check the connections between the connecting cable and the sensor, and make sure the finger is properly inserted. Be aware that nail varnish can interfere with readings, so try another finger.
  • B
    Brandon DanielsAug 20, 2025
    Why is there no FHR trace printed on my Huntleigh Measuring Instruments?
    • C
      Charles GallagherAug 20, 2025
      If the Huntleigh Measuring Instruments aren't printing an FHR trace, verify that the Print button has been pressed. Also, check that there is paper in the paper tray and that the paper tray is fully pushed in.
  • D
    Dawn EatonAug 23, 2025
    How to fix high % signal loss on Huntleigh Measuring Instruments?
    • H
      Hannah MillerAug 23, 2025
      If the Huntleigh Measuring Instruments display a high percentage of signal loss, check the transducer placement and ensure that the transducer is not damaged. You might also consider switching from Ultrasound to FECG.
  • T
    Theresa WebbAug 26, 2025
    How to display FHR signal on Huntleigh Measuring Instruments?
    • M
      michael96Aug 26, 2025
      If no FHR signal is displayed on the Huntleigh Measuring Instruments, ensure that Team 3 is switched on and that the FHR transducer is properly connected.
  • D
    donaldgonzalesAug 27, 2025
    What to do if the printer stops working on Huntleigh Measuring Instruments?
    • B
      Brian MurphyAug 27, 2025
      If the printer stops working on the Huntleigh Measuring Instruments, check the paper supply and feed. If this does not resolve the issue, swap the unit out. Note that trace data is stored in memory.
  • N
    nicholsnancyAug 30, 2025
    How to improve poor print quality on Huntleigh Measuring Instruments?
    • A
      Alejandro SandersAug 30, 2025
      If the print quality is poor on the Huntleigh Measuring Instruments, first ensure that the correct paper is loaded and that it is loaded correctly. Also, make sure the paper tray is fully pushed in. If the issue persists after reprinting, clean the print head.
  • F
    Francisco RhodesSep 1, 2025
    Why does my Huntleigh Measuring Instruments not beep when button pressed?
    • S
      Sabrina ValenzuelaSep 1, 2025
      If the Huntleigh Measuring Instruments do not beep when a button is pressed, check the sound setting.
  • X
    xmasonSep 3, 2025
    Why is the alarm not working on my Huntleigh Measuring Instruments?
    • P
      Patricia ReyesSep 3, 2025
      If the alarm is not working on the Huntleigh Measuring Instruments, it may be turned off. Check the alarm settings.
  • S
    Scott TylerSep 6, 2025
    What to do if no mark appears when pressing event marker on Huntleigh Measuring Instruments?
    • R
      Regina ThomasSep 6, 2025
      If no mark appears on the trace when the mother presses the event marker on the Huntleigh Measuring Instruments, check that the event marker is connected and ensure that enough time has elapsed since the button was last pressed.
  • J
    Javier JonesSep 8, 2025
    Why is my Huntleigh Measuring Instruments reporting no reading?
    • P
      palmerjenniferSep 8, 2025
      If the Huntleigh Measuring Instruments report no reading, check the cuff and hose. Then, try another measurement.

Summary

Safety

1.1 Warnings

Safety warnings for operating the device.

1.2 Infection Control

Guidelines for preventing infection during use and cleaning.

Introduction

2.1 Intended Use and Indications

Describes the purpose and applications of the Team 3 fetal monitor.

2.2 Unpacking; Preliminary Checks

Instructions for unpacking and initial inspection of the device.

Product Identification

3.1 Front Panel

Identifies components on the front interface of the device.

3.2 Rear Panel

Identifies connectors and ports on the rear of the device.

Setup

4.1 System Connection

Guidelines for connecting the device to other equipment.

4.4 Handling and Mounting

Instructions for safely handling and mounting the device.

Operation

5.1 Switching the Unit ON

Procedure for powering the fetal monitor on.

5.2 Application Screen

Overview of the main display and user interface.

5.3 Control Bar

Explains the functions available on the device's control bar.

5.4 Monitoring Parameters

Details on how to display and interpret monitored vital signs.

5.5 Switching the Unit OFF

Procedure for safely powering down the fetal monitor.

Monitoring Fetal Parameters

6.2 Ultrasound Monitoring

Step-by-step guide for using ultrasound to monitor fetal parameters.

6.4 Twins; Triplets Ultrasound Monitoring

Specific procedures for monitoring multiple fetuses simultaneously.

Monitoring Maternal Parameters

7.1 Contractions (using TOCO transducer)

How to monitor uterine contractions using the TOCO transducer.

7.5 Maternal Blood Pressure

Steps for taking maternal blood pressure measurements.

7.6 Maternal Oximetry

Guide for measuring maternal blood oxygen saturation.

Alarms

8.2 What is seen and heard

How alarm conditions are indicated visually and audibly.

8.3 Responding to alarms

Recommended user actions for different types of alarms.

Printing

9.5 Changing paper packs

Instructions for replacing the printer paper roll.

9.6 Loading printer paper

Visual guide for correctly loading paper into the printer.

9.8 Sample Trace (Sonicaid paper)

Example of a CTG trace with highlighted features.

Sonicaid Trend

10.2 Sonicaid Trend

Explanation of how Sonicaid Trend measures and calculates parameters.

10.4 Viewing Sonicaid Trend data

How to access and interpret trend data in numeric or graph views.

Dawes-Redman Antepartum Analysis

11.1 Intended Use

Purpose and application of the Dawes-Redman analysis feature.

11.3 The Dawes-Redman Criteria

Defines the criteria used for the Dawes-Redman analysis.

11.5 Using Dawes-Redman analysis

Steps to start and utilize the Dawes-Redman analysis feature.

Trouble Shooting

14.1 FHR

Common issues and solutions related to Fetal Heart Rate (FHR) monitoring.

14.2 Oximetry

Troubleshooting steps for issues with the oximetry sensor.

14.5 Printing

Solutions for common printing problems like paper jams or poor quality.

Care and Cleaning

15.1 General Care

General guidelines for handling and maintaining the device.

15.3 Cleaning and Disinfecting Patient Applied Parts

Methods for cleaning and disinfecting parts that contact the patient.

Maintenance

16.1 User maintenance

Routine checks and maintenance tasks for the equipment user.

16.5 Secure Settings

Accessing and managing secure settings and configurations.

Specifications

17.4 Transducers

Technical specifications for Ultrasound and FECG transducers.

17.6 Connections

Overview of all input and output connection ports on the device.

17.8 Default Settings

Default configurations for various device parameters, including alarms.

Electromagnetic Compatibility

Guidance and Manufacturer’s declaration - electromagnetic emissions

Information on the device's electromagnetic emissions and compliance.

Guidance and Manufacturer’s declaration - electromagnetic immunity

Information on the device's immunity to electromagnetic disturbances.

Ultrasound Safety Considerations

General

General safety principles and recommendations for using diagnostic ultrasound.

Acoustic Output

Technical data regarding the acoustic output of the ultrasound transducers.

Warranty & Service

Service Returns

Procedures and requirements for returning the device for service.

Huntleigh Sonicaid Team 3 Series Specifications

General IconGeneral
ManufacturerHuntleigh
ModelTeam 3 Series
DisplayLCD
Power SourceBattery or Mains
ConnectivityUSB
TOCO Range0-100
Paper Speed1 cm/min or 2 cm/min

Related product manuals