1 - 4 Site Preparation Pre-Installation Manual for i-Series Machines v387
foundation concrete.
2. The grout and anchor bolt manufacturers’ recommendations must be followed
to ensure full strength of the foundation.
3. After proper cure time, the anchor bolt must be capable of allowing a
minimum torque transmission of 271 Nm (200 ft-lb).
Machine Dimensions
Ensure there is a clear route from the loading dock to the machine location.
When moving a machine, be sure to allow adequate space for maneuvering. If door and
ceiling clearances appear to be close to approximate machine dimensions, measure the
machine first before attempting to move it.
Ensure there is adequate space for machine door clearances.
Allow additional space around the machine for servicing and safe operation. Leave room
for removing the coolant tank and the chip conveyor (if equipped).
The Model-specific Specifications document provides these machine dimensions:
Shipping Dimensions—height, width, length, and weight configuration of
the machine and auxiliary equipment as mounted to the skid. Shipping
dimensions are measured with the machine on its shipping pallet.
Operating Dimensions—width and length measurements that must be
considered for maintenance and service of the machine, such as opening all
enclosure and electrical power cabinet doors and location of auxiliary
equipment.

Table of Contents