Check the generator outlet (also see circuit diagram on
opposite page) for voltage between the following cable
colors:
Between yellow and brown (ground), plug (7)
disconnected
Multimeter reading: 12 volts +/- 1 volt
Same measurement with plug (7) connected
Multimeter reading: 12 volts +/- 1 volt
Between white and brown (ground), plug (8)
disconnected
Multimeter reading: 19 volts +/- 1 volt
Same measurement with plug (8) connected
Multimeter reading: 15 volts +/- 1 volt
NOTE: apply the black measuring tip on the
peak voltage adapter to the ground.
Check the regulator output voltage (9) (also see circuit
diagram on opposite page) with the cable color
yellow/red, controller (10) connected, fuse (11) removed:
Between yellow/red and brown (ground)
Multimeter reading: 14 volts +/- 1 volt
NOTE: apply the black measuring tip on the
peak voltage adapter to the brown (ground)
cable.
STATIC GENERATOR VALUES - KOKUSAN 4K-3B
Measuring conditions:
Cold engine
Seat and tank removed
–All plugs and the ground connections are in a non-corroding condition, plugs are tightly connected
Battery charged (if installed) and the light switch turned off
Decompression lever is pulled
Depress the kickstarter forcefully at least 5 times for each measurement
7
8
9
10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HUSABERG FE 550 and is the answer not in the manual?

HUSABERG FE 550 Specifications

General IconGeneral
Displacement549.1cc
Fuel systemKeihin FCR-MX 41
Cooling systemLiquid-cooled
StarterElectric starter
Transmission6 speed
Engine typeSingle cylinder, 4-stroke

Related product manuals