Electricsystem ~
Fig 5:5
Fit holding bar No. 5025060-01 on the flywheel
and puller No. 5025026-01 on the holding bar.
Remove the flywheel.
Changingthe starter pawls and springs
Placethe flywheel on the working bench with the
starter pawlsdownwards.
A
.Y
$,
Fig 5.6
Removethe three screwsretaining the armature
plate. Remove the bracket for the ignition cable
and disconnectthe short circuiting cable from the
stop switch. Then remove the armature plate.
Assembly is made in reverseorder.
When fitting the armature plate notice the marking
(fig. 5:7), ensuringa correct advanceignition. The
flywheel nut should be tightened by torque 40-43
Nm.
NOTE!
Before fitting a new flywheel remove every trace of rust
preventive especially on the hub.
Fig 5:8
Pushthe bearingpins of the starter pawlsout of
the flvwheel with a drift (~ 3 mm). Change
starte; pawlsand springs,and pressback t;e bear-
ing pinsfrom the fan side. Use Loctite AA in the
pin holesbefore putting the pins back. Check that
the pins reachthe bottom and that springsand
pawlswork properly.
To ensureproper connection between contact
springand ignition cable, useassemblingpliers
No. 5025006-01 for fitting the spark plug protec-
tor on the ignition cable.
We recommend the useof Lithium greaseNo.
5025042-01 when connectingthe ignition cable
to the spark plug protector.
For Husqvarna Parts Call 606-678-9623 or 606-561-4983