English - 19
NOTE!
After repairing, the chain brake must be in-
spected in line with the instruction below.
Functional inspection:
Do not turn on the engine when carrying out this
inspection.
Guide bar length Height
13”-18” 45 cm/18"
Hold the chain saw over a stable surface. The
distance between the guide bar and the sur-
face is shown in the table above.
Let go of the front handle and let the chain saw
drop toward the surface underneath.
When the guide bar hits the surface the chain
brake must trigger.
Safety equipment
Fig 10
WARNING!
Do not touch the muffler until it
has cooled. Risk of burns.
6.3 Dismantling the muffler
1
Remove the cylinder cover, mufer and gasket.
See gure 11.
2
If the mufer is tted with a spark arrestor mesh,
this is removed. If necessary, use the combination
spanner to push down the plate edge and remove
the spark arrestor mesh, See gure 11.
Cleaning and inspection
Clean and check all components carefully. Parts
must be replaced if cracked or show signs of
other defects. Always use original spare parts.
The spark arrestor mesh is best cleaned with a
wire brush.
The mesh must be replaced, if damaged. The
chain saw will overheat if the mesh is clogged
resulting in damage to the cylinder and piston.
Never use a chain saw with a clogged or defec-
tive mufer.
Fig 11

Other manuals for Husqvarna 543 XP

Related product manuals