EasyManua.ls Logo

Husqvarna 560XPG - Assembling the Start;Stop Control; Resistance Test - Stop Function

Husqvarna 560XPG
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English - 16
Safety equipment
“Dismantling the ignition module and flywheel”.
5. Cut open the shrink tube covering both cables
and shrink tubing that encloses the cable ends.
6. Clean the contact areas and check resistance
in the following way;
7. Test the resistance by connecting a multimeter
to the cable ends.
8. The stop switch is in the “on” position when the
button is held down (see figure 17) and in the
“off position when the button is in neutral.
9. Resistance can be 0.5 Ohm at most with the
power switch in the “on” position.
10. When assembling (see figure 18), pull the cable
ends apart and slide on a thicker shrink tube
over both cables. Then slide on the thinner
shrink tubes over each cable. Connect the
cable ends together. Slide the thinner shrink
tubes over the cable ends and heat the shrink
tube first on both cables separately. Slide the
thicker shrink tube over the thinner shrink tubes
and then heat the thicker shrink tube.
6.10 Assembling the start/stop control
1. Fit the new stop control (A) and tighten screw
(B) in place at a torque of 1 Nm. Slide in the
stop control in the rubber sleeve C and hook
the sleeve on the guide taps. See figure 15.
Fig 15
Fig 16
2. Attach the cables as outlined in figure 16.
3. Attach the air filter holder. See the “Assembling
the carburettor” chapter.
4. Fit air filter and cylinder cover.
6.10.1 Resistance test - stop function
Dismantle the ignition module as outlined in
Fig 18
Fig 17
NOTE!
The power switch must be in the “on” position
to get the correct reading. See figure 17.

Table of Contents