English - 37
2. SPECIAL MENU FUNCTIONS
Four values are shown on the display:
• Current: xx
= an indicator of how much power is needed to
maintain 2500 rpm (1750 rpm for 260 ACX). In
idling mode position, the normal value is
approximately 40-150 (for 260 ACX the value is
approximately 60-200).
• Average current: xx
= same type of indication value as above, but
measured as an average value during
approximately 8 hours of mowing time. A high
value indicates that the blade disc is blocked.
The current and average current are the values
compared and the difference between them
determines whether the Automower
®
should start
square mode cutting or not.
• Speed: xxxx rpm
The normal speed is approximately 2,500 rpm
(1750 rpm for 260 ACX).
• Voltage xxV
The battery voltage should be at least 18V in order
to evaluate the function of the cutting motor.
Press Arrow back to exit the test.
User interface (5-2-2)
This sub-menu, which is only available on 220 AC,
contains the following test functions:
Keypad
The button being tested is shown on the display and
the position ON or OFF. ON should be displayed
when the button is pressed down and OFF when the
button is released.
Press the Return arrow to end the test.
Display
Press YES repeatedly to light and dim all pixels and
to light a grid.
When one or more pixels do not light or dim as above
the display is defective.
Press Arrow back to exit the test.
WARNING
The blade disc rotates during the test
of the blade motor. Keep your hands
and feet at a safe distance.
Power & Motors
User interface
Loop
Sensors
Keypad
Display
Switches
Speaker
5-2-2