8.1 INPUTS (X) shows the status of each PLC input
FX1s PLC input specification.
X0 M-Code Lathe Interface Signal
X1 Manual/Auto switch
X2 Pusher Movement sensor
X3 Pusher Button (hand unit)
X4 Cross Slide Button (hand unit)
X5 Safety circuit Signal: b/f em.stop, m/c e-stop, guard hood, pressure sw.
X6 Material detection sensor
X7 M-Code-2 Lathe Interface Signal (optional)
X10 Insert Pusher forward sensor
X11 Pusher Home sensor
X12 E O B (End of Bar) sensor
X13 Main Pusher fully forward (eject) sensor
X14 Cross Slide in sensor (pushrod in line with spindle)
X15 Cross Slide out sensor (v-channel in line with spindle) / Collet closed
X16 Barfeed enable Lathe Interface Signal
X17 Collet open Lathe Interface Signal (Collet close on Doosan machine)
OUTPUTS (Y) shows the status of each PLC output
FX1s PLC output specification.
Y0 Cross Slide in
Y1 Cross Slide out
Y2 Pusher Forward
Y3 Pusher Retract
Y4 M-Finish-2 Lathe Interface Signal
Y5 Single Bar
Y6 Full Retract
Y7 Loader control
Y10 Cover Locks
Y11 Magazine Empty Lathe Interface Signal
Y12 Barfeed Ready Lathe Interface Signal
Y13 E O B Lathe Interface Signal
Y14 M-Finish Lathe Interface Signal
Y15 Spindle Disable Lathe Interface Signal